Previous revision
exercises:common:ensemble [2022/10/31 17:24] – [NVT Ensemble] jglanexercises:common:ensemble [2022/10/31 17:28] (current) – [NVT Ensemble] jglan
Line 219: Line 219:
 In the previous sections, you have already run NVE ensemble molecular dynamics calculations for liquid Ar. In this section, we will focus on the NVT ensembles.  In the previous sections, you have already run NVE ensemble molecular dynamics calculations for liquid Ar. In this section, we will focus on the NVT ensembles. 
  
-Although the most popular Nose-Hoover thermostat is used in other MD codes, the original Nose-Hoover thermostat has an ergodic issue. This has been solved by Mark Tuckerman et al. See [[https://doi.org/10.1063/1.463940 |Nose-Hoover Chain Thermostat]]  +Although the most popular Nose-Hoover thermostat is commonly-used in other MD codes, the original Nose-Hoover thermostat has an ergodic issue. This has been solved by Mark Tuckerman et al. See [[https://doi.org/10.1063/1.463940 |Nose-Hoover Chain Thermostat]]  
-In CP2K, the default length of the Nose-Hoover chain is set to 3. (see [[https://manual.cp2k.org/cp2k-2022_1-branch/CP2K_INPUT/MOTION/MD/THERMOSTAT/NOSE.html| %MOTION%MD%THERMOSTAT%NOSE]]+In CP2K, the default length of the Nose-Hoover chain is set to 3. (See Manual [[https://manual.cp2k.org/cp2k-2022_1-branch/CP2K_INPUT/MOTION/MD/THERMOSTAT/NOSE.html| %MOTION%MD%THERMOSTAT%NOSE]])
  
  
Line 234: Line 234:
       REGION MASSIVE       REGION MASSIVE
       &NOSE                    #Uses the Nose-Hoover thermostat       &NOSE                    #Uses the Nose-Hoover thermostat
-        TIMECON 1000           #timeconstant of the thermostat chain, how often does thermostat adjust your system +        TIMECON 100           #timeconstant of the thermostat chain, how often does the thermostat adjust your system 
       &END NOSE       &END NOSE
     &END     &END
Line 240: Line 240:
      
  
 +Alternatively, one can also use [[https://manual.cp2k.org/cp2k-2022_1-branch/CP2K_INPUT/MOTION/MD/THERMOSTAT/CSVR.html| Canonical sampling through velocity rescaling
 +(CSVR)]] as developed by Giovanni [[https://doi.org/10.1063/1.2408420 |Bussi et al. ]]
 +  &MD
 +    ENSEMBLE NVT
 +    STEPS 3000
 +    TIMESTEP 5
 +    TEMPERATURE 298
 +    &THERMOSTAT
 +      &CSVR                    
 +        TIMECON 100           #timeconstant of the CSVR, how often does the thermostat adjust your system 
 +      &END CSVR
 +    &END
 +  &END MD
 +  
 ===== NPT Ensemble  ===== ===== NPT Ensemble  =====
  